Refrigerant Gas Leak Detection for Plant Rooms, Cold Stores and VRF Systems

Aqualeak supplies, installs, commissions and maintains MSA Bacharach refrigerant gas detectors and control panels for plant rooms, cold stores and occupied spaces with VRF air conditioning, across the UK.

A refrigerant gas detection system watches the air in rooms where refrigerant could leak, such as plant rooms, cold stores and rooms served by VRF or VRV air conditioning. When the gas level passes a set point, the detector sounds an alarm and its relays can start ventilation, close valves or alert the building management system, so a leak is dealt with before it becomes a safety risk or an expensive loss of refrigerant.

We supply and install the MSA Bacharach MGS-400 range and the MVR-300, from a single standalone gas leak detector up to control panels that monitor several detectors from one place. The MGS-450 can also be fitted with sensors for toxic and combustible gases such as ammonia, CO2 and hydrocarbon refrigerants. We have worked with MSA since launching our refrigerant gas detection service in 2024.

mgs 402 gas detector control panel
mgs 450 refrigerant gas leak detector
mgs 408 refrigerant gas detection alarm panel for multiple areas
Download brochure for the MGS-400 range

Which refrigerant gas detector for which space?

The right detector depends on the room, the refrigerant and how many points need watching. Plant rooms and cold stores usually need fixed detectors reporting to a panel. Hotel bedrooms and offices on VRF systems need a discreet detector in each room.

évenementiels Suggested detectorCe qu'il fait
Plant room or chiller roomMGS-450Fixed detector with its own 72 dB alarm and three relays for ventilation, beacons or shut off. Works on its own or reports to an MGS-402 or MGS-408 panel.
Cold store or walk-in freezerMGS-450 with MGS-402Most MGS-450 sensor types are rated down to -40°C, and there is an IP66 enclosure option. The panel sits outside the cold room so staff see the status before they go in.
Hotel, office or apartment rooms on VRF or VRVMVR-300Flush mounted in a standard 3-gang box. Detects R-410A, R-407C, R-404A or R-32 and alarms in the room while telling the BMS.
Several detectors on one siteMGS-408 panelUp to eight detectors on one panel, with live readings on the display, an SD card event log and a Modbus link to the BMS.

Refrigerant gas detectors and gas detection panels

Each detector can work alone, with its own alarm and relays, or report to a gas detection control panel. The MGS-402 panel takes two detectors and the MGS-408 takes eight, giving one place to see every reading, silence alarms and connect to the building management system by Modbus.

MSA Bacharach MGS-450

Refrigerant, toxic and combustible gas detector

  • Cost effective and simple-to-use fixed gas detector that helps customers comply with a range of refrigeration safety standards, including ASHRAE 15, EN 378 and CSA-B52
  • Can be used as a standalone detector or connectable to multi-detector controllers such as MGS-402 and MGS-408
  • Built-in 72 dB buzzer and tri-colour LED, meeting the EN 378 and ASHRAE 15 alarm requirements without extra hardware
  • Sensor options for refrigerants, ammonia, CO2, CO, oxygen and hydrocarbon refrigerants such as R-290
  • Most sensor types operate from -40°C to +50°C, and the detector comes in IP41 and IP66 enclosure versions
  • Plug-and-play, pre-calibrated sensor modules allow for quick, simple sensor replacement
  • Temperature-compensated measurements mitigate false alarms and optimize accuracy in refrigeration applications
  • Configurable analog output and Modbus communications for integration with third-party BMS / BAS control systems
  • Three user-configurable relays (fault, low and high alarm) may be used to activate external beacons / sounders, ventilation or other counter-measures
  • MGS-400 mobile app (available for Android and iOS) allows users to interface via Bluetooth with gas detectors for easy commissioning and maintenance without specialty tools or training

Exemples d'applications: Machinery rooms, cold storage rooms, walk-in freezers, food preparation areas

MSA Bacharach MGS-402

2-channel gas detection control panel

  • Central status monitoring panel for up to two MGS-400 series gas detectors, to alert to the presence of refrigerant, toxic and combustible gases
  • Tri-colour LED indicators provide “at-a-glance” system / alarm status
  • Integrated audible / visual alarms with push button silence for refrigeration safety compliance
  • Designed for operation in refrigeration applications, suitable for use in environments down to -40°C, in an IP66 enclosure
  • Two configurable analogue outputs and Modbus communications for integration with the MGS-408 controller or third-party BMS control systems
  • Three user-configurable relays (fault, low and high alarm) may be used to activate external beacons / sounders, ventilation or other counter-measures

Exemples d'applications: Machinery rooms, cold storage rooms, walk-in freezers, food preparation areas

MSA Bacharach MGS-408

8-channel gas detection control panel

  • Central status monitoring panel for up to eight MGS-400 series gas detectors, to alert to the presence of refrigerant, toxic and combustible gases and help comply with refrigeration safety standards such as EN 378 and ASHRAE 15
  • Digital display shows real-time concentration readings for all connected gas detectors and makes configuration and self-diagnostics intuitive
  • Tri-colour LED indicators provide “at-a-glance” system / alarm status
  • Integrated SD card retains the alarm / status history of the gas detection system
  • Modbus communications for integration with third-party BMS control systems
  • Integrated audible / visual alarms with push button silence for refrigeration safety compliance
  • Three user-configurable relays (fault, low and high alarm) may be used to activate external beacons / sounders, ventilation or other counter-measures

Exemples d'applications: Machinery rooms, cold storage rooms, walk-in freezers, food preparation areas

MSA Bacharach MVR-300

VRF refrigerant leak detector for occupied spaces

  • Specifically designed to provide continuous monitoring for refrigerant gas associated with high-efficiency, high volume refrigerant cooling and heating systems, such as Variable Refrigerant Flow (VRF) and Variable Refrigerant Volume (VRV) systems
  • Detects R-410A, R-407C, R-404A or R-32, with two alarm levels and an 80 dB buzzer
  • Audible and visual alarms to quickly alert occupants, while simultaneously communicating with BMS/BAS
  • Two relays that can be used to initiate counter-measures, such as valve closure, trigger alarm devices and exhaust fans
  • On-board Modbus RTU interface provides real-time information about concentrations, status and settings. It also enables custom configuration of the MVR-300 to any application specific requirements using multiple Modbus registers
  • Fits in standard 3-gang electrical boxes for easy installation
  • This gas leak detector is low profile / flush mount for aesthetically non-intrusive appearance
  • Self-diagnostics and simple field calibration. MSA recommends testing or recalibration every six months
  • Unique plug-in field replaceable pre-calibrated sensor for low cost of ownership

Exemples d'applications: Hotels, dormitories, hospitals, office buildings, apartment buildings

When is refrigerant gas detection required?

Three sets of rules usually decide whether a building needs refrigerant gas detection. We check them against your plant and drawings before recommending anything.

EN 378: safety of refrigerating systems

EN 378 calls for gas detection where a leak could push the refrigerant concentration in a room past its practical limit. That limit is worked out from the refrigerant charge and the volume of the smallest room the system serves. It usually applies to machinery and plant rooms, and to small occupied rooms such as hotel bedrooms on VRF or VRV systems, where the whole charge could leak into one room. Where detection is needed, the alarm has to be audible and visible, and it can also start ventilation or shut the system down.

F-gas rules: leak checks and automatic leak detection

Under the F-gas rules in Great Britain, equipment holding 500 tonnes CO2 equivalent or more of F gas must have an automatic leak detection system that alerts the operator or service company, and that system must itself be checked every year. On smaller equipment, fitting leak detection doubles the time allowed between leak checks. The government’s guide to checking F gas equipment for leaks sets out the thresholds. Northern Ireland follows the EU F-gas regulation.

BREEAM: Pol 01 impact of refrigerants

BREEAM awards a credit under Pol 01 for a permanent automated refrigerant leak detection system that monitors continuously and can automatically isolate and contain the remaining charge when it finds a leak. Our detectors’ relays can drive that isolation. Whether the credit is awarded depends on the whole system design and the assessor. See our BREEAM leak detection page for the water leak credit as well.

Water and gas leak detection from one contractor

Refrigerant gas detection and water leak detection often sit in the same M&E package. Because we install both, one survey, one installation team and one maintenance visit can cover the plant room detectors and the commercial water leak detection under the pipework, with alarms going to the same building management system.

Where we fit refrigerant gas detection

  • Hôtels, with VRF air conditioning in guest rooms
  • Bureaux and fit outs with VRF or VRV systems
  • Immeubles d'appartement and student accommodation
  • Supermarket and food cold stores, walk-in freezers and kitchens
  • Plant rooms, chiller rooms and heat pump installations

Contacter Aqualeak

To talk to a refrigerant gas detection specialist about a plant room, cold store or VRF project, or to arrange a survey, please visit the page contact to send an enquiry or call us on 01249 715698.

contactez-nous.

Refrigerant gas detection: common questions

Often, yes. EN 378, the safety standard for refrigerating systems, calls for detection wherever a leak could take the refrigerant concentration in a room past its practical limit, which usually includes plant rooms and small rooms served by VRF systems. Separately, under the GB F-gas rules, equipment holding 500 tonnes CO2 equivalent or more must have an automatic leak detection system that is checked every year. We can review your plant and tell you where detection is needed.

Close to where a leak is most likely, such as compressors, valves, joints and indoor units. Most refrigerants are heavier than air, so detectors usually go low down. Ammonia is lighter than air, so its detectors go high. The exact position depends on the refrigerant, the room and the airflow, so we set it out at survey.

The detector sounds a local alarm and shows a red light. The MGS-450 has a 72 dB buzzer and the MVR-300 an 80 dB buzzer. Their relays can start extract ventilation, close a valve, switch on beacons or sounders, or shut the system down, and a Modbus link can tell the building management system at the same time. The MGS-408 panel also logs every event to an SD card.

Often they do. Hotel bedrooms are small, and a VRF system can hold a large charge of refrigerant, so a leak into one room can exceed the practical limit set in EN 378. The MVR-300 is made for this: it fits flush in a standard 3-gang box, alarms in the room and reports to the BMS.

It can. BREEAM’s Pol 01 credit for refrigerants includes one credit for a permanent automated leak detection system that monitors continuously and can automatically isolate and contain the remaining refrigerant when it finds a leak. Our detectors’ relays can drive that isolation, but the credit depends on the whole system design and the assessor.

Yes. We supply, install, commission and maintain MSA Bacharach detectors and panels across the UK. MSA recommends testing or recalibrating the MVR-300 every six months, and we can cover that alongside servicing any water leak detection on the same site.

Still have a question? Call us on 01249 715698 or envoyez-nous une demande.